Permian OSHA Watch

← All companies

SONIC CONNECTORS, LTD.

Recorded by OSHA as: SONIC CONNECTORS, LTD.

2inspections
3citation items
$18,711current penalties
$41,898initial penalties

Inspections

OpenedSiteTypeCitationsPenaltyStatusOSHA record
2024-07-31WATCHMAN 30-25 UB 2 WA 10-MILES NE FROM COYANOSA, COYANOSA, TX
Pecos County · NAICS 213112
Planned2$10,000Closed 2024-10-16#347660664
2023-10-27GARDENDALE BLUE WELL 0904, GARDEN CITY, TX
Glasscock County · NAICS 213112
Referral1$8,711Closed 2024-03-01#347072241

Citations

IssuedCompanySiteStandardTypeCurrent penalty
2024-08-16SONIC CONNECTORS, LTD.COYANOSA, TX1910.28(b)(1)(i)
Fall protection – guardrails, safety nets or personal fall arrest required at 4 ft+ (e.g.,…
Serious$10,000
2024-08-16SONIC CONNECTORS, LTD.COYANOSA, TX1910.30(c)(3)
Training workers on fall hazards and equipment.…
Serious$0
2024-02-07SONIC CONNECTORS, LTD.GARDEN CITY, TX1910.106(b)(6)
Flammable liquids – storage, handling and ignition-source control.…
Serious$8,711
Disclaimer. Data from the U.S. Department of Labor, OSHA enforcement database (data.dol.gov), filtered to oil & gas NAICS codes (211, 213111, 213112, 486, 237120) and Permian Basin counties by site ZIP/city. Citations and penalties are not final until a case is closed and may be contested, reduced or withdrawn. Company names are shown as recorded by OSHA and grouped by an automated name match; a name may match multiple distinct legal entities, and one company may appear under several names. Inspections in New Mexico occur under federal OSHA jurisdiction for private employers; Texas is a federal-OSHA state. This site is independent and not affiliated with OSHA or DOL. Verify any record at osha.gov before relying on it.